Recommendations for Mechanical Equipment / HVAC

Adhere to a strict maintenance schedule for HVAC equipment and make sure it is working properly. Use the highest efficiency filters compatible with current HVAC system, and if necessary, consider retrofitting the system to increase filtration capabilities. Maintain relative humidity between 30% and 50%.

Use non-chemical methods to maintain HVAC ducts free of particulate matter, dust, and debris, such as physical removal or use of vacuums. Do not use the HVAC system to disperse fragrances or other materials.

Seal return air openings into HVAC system during remodeling and exhaust directly to the outdoors, by temporarily removing window glazing if necessary.

Use demand controlled ventilation (DCV) that provides liberal amounts of air flow and outdoor air ventilation. Before a building is re-occupied in the morning or after weekends, flush with at least three complete outdoor air exchanges.

Create door and window-opening protocol to maintain proper pressure relationships and air flow in the building. Educate and provide protocol to staff and other building occupants. Policy should include provision that allows chemically sensitive and other individuals to open windows on a temporary or regular basis, as needed because of a health condition. Windows should also be permitted to be opened by occupants when the HVAC system is not working or shut off, such as may occur during nights and weekends.

Make maximum use of economizer cycle. Avoid energy conservation practices that reduce intake of outside air below minimum requirements.

Avoid or minimize the use of humidifiers in the building's HVAC system. Prohibit the use of personal humidifiers except when an occupant has a medical need for one. Maintain the cleanliness of all humidifier equipment and use the minimum amount of water treatment chemicals necessary to control dissolved solids and pH and prevent antimicrobial contamination. Do not allow the use of portable air "cleaners" that emit ozone.

Repair plumbing with least toxic, low-VOC materials. Use snakes or other mechanical methods to clear clogged drains. Use bacterial enzymes to prevent drain clogs. Inspect floor and other drains, especially those that are infrequently used, to ensure there is water in the P-traps, thereby avoiding sewer gas backup. Treat grease traps daily with bacterial enzymes.